Known Issues - Web-based SAP

General

It is not recommended to work with other Web-based add-ins when the UFT SAP Solutions Add-in is loaded. The SAP Solutions Add-in modifies certain Web configuration settings that may affect other add-ins or applications.

Back to top

Object Identification

  • In some cases, when more than one browser is open during the test run, UFT is unable to correctly identify certain objects.

    Workaround: Clear the Enable Smart Identification check box for the Browser test objects in the Object Repository window. You may also want to disable the Enable Smart Identification option for Browser test objects in the Object Identification Dialog Box for future test recording.

  • Minimized or collapsed iViews may not be recognized correctly.

  • In some cases, a frame in SAP Enterprise Portal may be recognized as a Web Frame object instead of an iView object. In some of these, the frame name is generated dynamically. Because the Web Frame object uses the name property to identify the object, you must modify the recorded name value to use an appropriate regular expression so that UFT will be able to recognize it during the test run.

  • When using the Object Spy or creating a checkpoint on an object inside an SAP Web table cell, UFT may recognize the object as a WebElement (and not as the appropriate SAP Web object), if a click has not yet been performed on the object.

    Workaround: Click on the object inside the SAP Web table cell before using the Object Spy or creating a checkpoint on it.

  • Avoid using an Active Screen that was captured when a pop-up dialog was open to add an object from the main window to the object repository. Doing this results in an incorrect object hierarchy in the object repository.

Back to top

Recording

  • When recording and running steps on a table control, only the table content that is visible on the client is actually available.

  • Operations on the iView option menu and on objects within the page title bar of SAP Enterprise Portal are recorded as Web operations on the Frame object and not as SAP operations on the iView object.

  • Dragging the SAP GUI for HTML table scroll bar is not recorded.

    Workaround: You can record scrolling in SAP GUI for HTML tables by clicking the scroll button. Alternatively, use the Step Generator or Editor to insert a SAPTable.Object.DoScroll("up") or SAPTable.Object.DoScroll("down") statement in your test.

  • When recording a SAPList object, you need to click the input part of the list, not its button part in order to enable UFT to recognize the object.

  • The Active Screen may not display the entire HTML page captured while recording your test.

    Workaround: Resize the Active Screen so that it best fits the HTML page size.

Back to top

Running tests on SAP applications

  • During a run session, the SAP platform response time may be slower than the time it takes for UFT to run the corresponding step.

    Workaround: Add a Wait statement prior to the relevant step.

  • In some cases, when running tests on SAPEdit, SAPNavigationBar, or SAPPortal, you may receive a Cannot find object error. 

    Workaround: Do one of the following:

    • Ensure that the object properties are unique and correct.

    • Modify the registry as specified below:

      For 32 bit computers: In the HKEY_LOCAL_MACHINE\Software\Mercury Interactive\QuickTestProfessional\MicTest\AbortIfHangInSendData key, set the value of DWORD to 0.

      For 64-bit computers: In the HKEY_LOCAL_MACHINE\Software\Wow6432Node\Mercury Interactive\QuickTestProfessional\MicTest\AbortIfHangInSendData key, set the value of DWORD to 0.

  • When running a test on an ITS frame in an SAP Enterprise Portal iView, the ITS menu sometimes fails to operate properly.

    Workaround: Enlarge the iView size and/or increase the Object Synchronization Timeout and then run the test again.

  • When using UFT to test Web-based CRM systems, make sure that the CRM system is in test mode. You can do this by adding "?sap-testmode=X" to the URL.

  • On some SAPTable objects, the FindRowByCellContent method does not work correctly if the row to find is not visible in the table. If this happens, add an extra step to scroll to make the row visible.

Back to top

SAPUI5-specific limitations

  • Because the SAPUI5 add-in supports both desktop and mobile applications, not all methods for all objects are supported for both desktop and mobile applications.

  • When running a test or component on SAPUI5 test objects, application Alert messages for some objects are not displayed.

    Workaround: Do one of the following:

    • Make sure your test does not contain steps that need to be performed on the Alert message.

    • Add an If statement to your test for the object that triggers the alert to check if the Alert exists.

  • If your SAPUI5 application contains nested table objects, inserting a checkpoint on the nested table object shows only the parent SAPUITable object.

    Workaround: Select the nested WebTable objects and create checkpoints for the WebTable object instead of the parent SAPUITable object.

  • When using the Object Spy to view an SAPUIMenu object or recording an SAPUIMenu object which is hidden in closed status, you may be unable to:

    • Add the menu object to the repository on Firefox and Chrome browsers with the Add Object to the Repository button

    • Record the object on Chrome browsers.

    • Add checkpoint or output value steps in Firefox and Chrome browsers

  • When working with mobile SAPUI5 applications, UFT cannot use the Object Spy on some disabled controls (like the SAPUIButton and SAPUITextEdit) due to the application object properties.

  • When working in Internet Explorer 11, if your application requires you to scroll down to perform a button click, the SAPUIButton.Click method does not click the button.

    Workaround: Use a SAPUIButton.Submit method instead.

  • Using the ChildObjects method on some objects returns a different result between browsers.

Back to top

SAPWDJ-specific limitations

  • If you try to record objects in a SAP WDJ application without the SAPWDJ add-in loaded, UFT records only some of the objects correctly.

    Workaround: Restart UFT and load the SAP WDJ Add-in.

  • During a run session, the response time of the SAP platform running a SAP Web Dynpro Java (WDJ) application may be slower than the time it takes for UFT to run the corresponding step.

    Workaround: Add a Wait statement prior to the relevant step or set the Delay each step execution option in the Test Runs pane of the Options dialog box (Tools > Options > GUI Testing tab > Test Runs node) to the necessary wait period (in milliseconds)

  • The following functionalities are not supported for SAP WDJ applications:

    • Selection of non-visible table rows

    • Interaction with the application scroll bar

    • Menus inside table cells

    • Date navigator windows inside the application

  • When recording steps on an SAPWDJTable object, the SelectCell method is not always recorded if you are selecting non-editable cells.

  • If your table contains links that open a popup window, when using the SAPWDJTable.SelectItemInCell method to click the link, UFT does not run the .SelectItemInCell properly.

    Workaround: Associate the linkFuncLibr function library with your test. This function library is found at <UFT installation directory>\dat\Extensibility\Web\Toolkits\SAPWDJ\FunctionLibraries\linkFuncLibr.qfl.

Back to top

SAP Business Networks applications

  • Spying or adding checkpoints on an SAPWebExt List in SAP FieldGlass is not supported.

  • Checkpoints on SAPWebExtTable objects are not supported.

    Workaround: Do one of the following:

    • Restart UFT, clear the SAPWebExt addin and then add a checkpoint on a WebTable object.

    • Use the .GetCellData method

    • Add a checkpoint on the child WebTable of a SAPWebExtTable object.

Back to top

SAP WebDynpro ABAP applications

  • A click operation on a SAPTable object is not recorded.

    Workaround: Manually add the object as a WebElement and add a WebElement. Click step to your test.

  • If a table object disappears in the application immediately after a select operation is performed, SelectCell methods are not recorded on the table object.

    Workaround: Manually add the SAPTable.SelectCell method after recording.

  • For some table objects which display dynamically during scrolling, the SAPTable.GetCellData method may not retrieve invisible cell data which is invisible.

    Workaround: Add steps to click the arrow of scroll bar to make the row visible and then use the GetCellData method with current row value.

    For example:

    'get value in row 1
    print Browser("WDR_TEST_C_TABLE [Web").Page("Web Dynpro Test Suite").SAPTable("[Demo Table Part 1]").GetCellData (2,4)
    For Iterator = 1 To 4 Step 1
        wait 1
        Browser("WDR_TEST_C_TABLE [Web").Page("Web Dynpro Test Suite").SAPButton("SAPButton_2").Click
    Next
    'get value in row 7 which is shown in line 4 after scroll
    print Browser("WDR_TEST_C_TABLE [Web").Page("Web Dynpro Test Suite").SAPTable("[Demo Table Part 1]").GetCellData (4,4)
  • When using the SelectCell method on SAPTable objects in SAP WDA 7.5 applications:

    • If the table cell is located in a popup dialog window that closes immediately after clicking, UFT cannot record the action.

    • You may need to click twice on the table cell to enable UFT to record the action.

Back to top